What is Water Demineralization?
Water desalination is the process of removing dissolved mineral ions from water to prepare low-salt pure water using chemical or physical methods. Since minerals in natural water primarily exist as anions and cations, the core of demineralization lies in the separation of these ions.
It is easy to confuse demineralization with water softening or seawater desalination. Water softening targets only calcium and magnesium ions; it does not significantly alter the total salt content and is primarily used to prevent scale formation. Seawater desalination targets high-salinity seawater and brackish water, reducing the salinity from tens of thousands of mg/L to usable levels, and is mostly used for large-scale primary desalination. In contrast, industrial water demineralization aims to remove the vast majority of anions and cations, often resulting in product water with salt concentrations as low as micrograms per liter (µg/L). The source water for this process is typically tap water or surface water.
Ionic impurities in water can interfere with industrial production. Calcium and magnesium ions tend to form scale in boilers, which reduces heat-transfer efficiency and can even damage boiler tubes, while chloride and sulfate ions can cause equipment corrosion. Industries such as electronics and pharmaceuticals have a very low tolerance for trace metal ions, and in the food and beverage sector, fluctuations in mineral content can affect both taste and batch-to-batch consistency.
Water used for power plant boiler feedwater, electronic ultrapure water, pharmaceutical purified water, chemical process water, and laboratory analytical water all require desalination treatment.
Ion Exchange Process Basics
Ion exchange is currently one of the most widely used technologies in the field of industrial water desalination. Its core is to use the exchangeable ions on the ion exchange resin to exchange and react with the impurity ions in the water to achieve the directional removal of salt.
How Ion Exchange Works
Cation exchange is the first step in desalination.Cation exchange resin has exchangeable hydrogen ions. When water flows through the resin layer, the positively charged calcium ions, magnesium ions, sodium ions, ferrous ions, etc. in the water will be adsorbed by the functional groups of the resin. At the same time, the hydrogen ions on the resin are released into the water.After cation exchange, all the cations in the water are replaced with hydrogen ions, and the effluent is acidic.
Anion exchange followed closely.The cationic-treated water enters the anion exchange resin, which has exchangeable hydroxide ions on the resin. The negatively charged chloride ions, sulfate, nitrate, bicarbonate and other anions in the water will be exchanged with the hydroxide ions, which are adsorbed and fixed by the resin, and the hydroxide ions enter the water.
The hydrogen ions released from the cationic resin and the hydroxide ions released from the anionic resin will combine in the water to form water molecules.All kinds of salts originally dissolved in water are finally converted into pure water after two exchanges of anions and anions. This is the core logic of the preparation of desalinated water by ion exchange method.
Overview of Commonly Used Resin Types
|
Resin Type |
Functional Group |
Exchange Capacity |
Application Scenario |
Regenerant |
|
Strong Acid Cation (SAC) |
Sulfonic acid group |
Ionizes over a wide pH range; removes all cations |
Base cation resin for demineralization systems |
Hydrochloric acid or sulfuric acid |
|
Weak Acid Cation (WAC) |
Carboxylic acid group |
Functions under weakly acidic to neutral conditions; removes only carbonate hardness |
Pre-treatment for high-alkalinity, high-hardness raw water to reduce acid consumption |
Hydrochloric acid or sulfuric acid |
|
Strong Base Anion (SBA) |
Quaternary ammonium group |
Ionizes over a wide pH range; removes all anions, including silicate |
Essential for deep demineralization and silica removal |
Sodium hydroxide |
|
Weak Base Anion (WBA) |
Primary/secondary/tertiary amine groups |
Functions under acidic conditions; adsorbs only strong acid anions, does not remove silicate |
Pre-treatment protection for strong base anion resin; resistant to organic fouling |
Sodium hydroxide |
|
Mixed Bed Resin |
Cation and anion resins mixed in proportion |
Cation and anion exchange simultaneously; high effluent purity |
Terminal deep polishing |
Acid and alkali regenerated separately |
Mainstream Desalination System Configuration
Industrial systems will choose different configurations according to raw water quality, water production requirements, and operating costs.Common forms are two-bed, three-bed, mixed-bed, and reverse osmosis combined processes.
Two-Bed Desalination System
Two beds are the most basic configuration.The cation exchanger and the anion exchanger are connected in series, and the raw water first passes through the yang bed and then into the yin bed.When the water passes through the anode resin layer from top to bottom, the cations are adsorbed and the hydrogen ions are released.The effluent is acidic, and then enters the yin bed, the anions are adsorbed, the hydroxides are released, and the two combine to form water.
The advantages are simple structure, low investment and easy maintenance.The conductivity of water produced can usually be reduced to 1 to 10 µS/cm, which can meet the needs of most medium and low pressure boilers and general chemical process water.The limitations are also obvious.When the alkalinity of raw water is high, the bicarbonate in the effluent of the Yang bed exists in the form of carbonic acid. After entering the yin bed, the exchange capacity of strong alkaline yin resin is consumed, which increases the consumption of regenerated alkali.The purity of the single-stage two-bed effluent is limited and cannot meet the requirements of high-purity water.
Three-Bed Desalination System
The three-bed is based on the two-bed, and a carbon remover is added between the yang bed and the yin bed to form a configuration of the yang bed, the carbon remover, and the yin bed.This is currently the most commonly used classic process for industrial desalination.
The pH of the effluent from the sun bed is usually lower than 4.5. The bicarbonate in the water reacts with hydrogen ions to produce carbon dioxide and water.Carbon dioxide is a gas and does not require ion exchange to remove it.The decarbonizer allows the water to come into contact with the air countercurrent, blowing out most of the carbon dioxide, and the content can usually be reduced to less than 5 mg/L after treatment.The carbonate load originally borne by the yin resin has been greatly reduced, and the amount of strong alkaline yin resin can be reduced by more than 30%. The consumption of regenerated alkali has decreased synchronously, and the yin bed cycle has been extended.
For surface water and tap water with high alkalinity, the economy of the three-bed system is significantly better than that of the two-bed system, and it is the preferred basic configuration for most industrial desalination projects.
Mixed Bed Desalination System
The mixed bed mixes the male resin and the female resin proportionally and fills them in the same exchange tank.Water flows through the mixed resin layer, and the anionic ions are exchanged by the corresponding resin at the same time, which is equivalent to countless miniature Yang beds and yin beds in series, and the reaction is very thorough.
The mixed bed belongs to a deep polishing unit, and the water quality of the water produced is much higher than that of the fixed bed combination of Yang and yin beds.The water production resistivity of conventional mixed beds can reach 10 to 15 MW·cm, and the optimized refined mixed bed can be close to the theoretical pure water standard of 18.2 MW·cm.The mixed bed is mostly used in high-standard scenarios such as high-pressure boiler supply water for power plants, ultrapure water for electronic semiconductor, and water for pharmaceutical injection. It is generally not used alone, but is mostly located in the Yang-yin bed or reverse osmosis system for terminal finishing.
Reverse Osmosis Plus Ion Exchange Combination
With the popularization of reverse osmosis technology, more and more systems adopt a combined process of reverse osmosis and ion exchange, taking into account the processing efficiency and operating costs.Reverse osmosis can remove more than 98% of dissolved salts, organic matter and colloids.As a pretreatment, it significantly reduces the salt content of the water inlet of the subsequent ion exchange unit.The back is polished with a mixed bed, which can not only obtain high-purity water, but also extend the resin regeneration cycle and reduce chemical consumption.
There are two common combinations.One is reverse osmosis and mixed bed.The other is reverse osmosis plus EDI electrodeionization.Compared with the full ion exchange system, the RO front is more suitable for high TDS raw water.When the TDS is greater than 500 mg/L, the overall operating cost is lower and the wastewater discharge is less.
How to Judge the Process Selection
The core of selection looks at two indicators.First, the salt content and ion composition of raw water.The second is the purity requirements of the terminal water production.Raw water has low TDS and general water production requirements, and traditional Yang-yin beds are more economical.If raw water has a high salt content or high water production requirements, the combination of RO and ion exchange polishing is preferred.
|
Configuration |
Main Components |
Typical Effluent Quality |
Application Scenario |
Limitations |
|
Two-bed system |
Cation bed + anion bed |
Conductivity 1–10 μS/cm |
Medium/low-pressure boilers, general chemical processes |
Limited effluent purity; high alkali consumption at high alkalinity |
|
Three-bed system |
Cation bed, decarbonator, anion bed |
Conductivity 1–10 μS/cm, CO₂ below 5 mg/L |
High-alkalinity surface water, tap water, basic industrial demineralization |
Still cannot meet high-purity water standards |
|
Mixed bed system |
Cation and anion resins mixed in a single vessel |
Resistivity 10–15 MΩ·cm; near 18.2 MΩ·cm for polishing |
High-pressure boilers, semiconductors, pharmaceutical terminal polishing |
Not used alone; requires pre-treatment |
|
RO + ion exchange |
Reverse osmosis + mixed bed or EDI |
High purity, meeting standards at the polishing unit level |
High-TDS raw water, high-purity water requirements |
High upfront equipment investment |
Key Water Quality Indicators To Judge The Quality Of Effluent
To judge the operating effect of a desalination system, a series of water quality parameters need to be paid attention to.Different indicators correspond to different control meanings.
- Total dissolved solids in water TDS: The total mass of all dissolved inorganic salts and organic matter in water, in mg/L, is an intuitive indicator to measure the total salt content, which directly determines the system load and process selection.
- Water conductivity: Reflects the conductivity of ions in water, in µS/cm.The higher the ion concentration, the higher the conductivity, which is the most commonly used online monitoring index for daily operation.The conductivity of conventional two-bed water production is generally 1 to 10 µS/cm.
- Electrical resistivity: The reciprocal of electrical conductivity, in MW·cm, is mostly used for the characteristics of high-purity water.The theoretical pure water resistivity at 25℃ is 18.25MW·cm, and the higher the value, the lower the ion content.The conductivity value of high-purity water is too small and the reading error is large. The resistivity of mixed-bed water is usually monitored.
- The pH value of the water: it is determined by the type of residual ions in the water.The effluent from the Yang bed is acidic, the effluent from the yin bed is close to neutral, and the pH of the water produced from the mixed bed is usually 6.5 to 7.5.Abnormal pH often indicates resin failure or incomplete regeneration.
- Total hardness of calcium: The total concentration of calcium and magnesium ions, measured in mmol/L or mg/L in terms of CACO₃.Hardness is the core index of yangbed removal, and excessive hardness of boiler water will directly bring the risk of fouling.
- Silica content: the most difficult component of anions to remove.High-pressure boilers require a silicon content of less than 20 µg/L, and even lower requirements for ultrapure water.Whether silicon meets the standards is the key basis for judging the end point of operation of strong alkaline anointed resin or mixed bed.
- Total organic carbon in water TOC: The carbon content of soluble and suspended organic matter in water.Organic matter will contaminate the resin, causing the exchange capacity to decrease and the effluent to deteriorate.
|
Application Scenario |
Typical Parameter Requirements |
|
Low-pressure industrial boiler make-up water |
Conductivity < 10 μS/cm, hardness < 0.03 mmol/L |
|
High-pressure power plant boiler make-up water |
Conductivity < 0.2 μS/cm, silica < 20 μg/L |
|
Electronic-grade ultrapure water |
Resistivity 18.2 MΩ·cm, ion concentrations controlled at ng/L level |
How to Choose Ion Exchange Resin
Choosing the right resin is the key to the stable operation of the system and cost control.The selection should not only look at the type of resin, but should be combined with the quality of raw water, water production requirements, system design, and operating conditions to make a comprehensive judgment.
First Analyze the Composition of Raw Water
The first step in the selection is to obtain a complete raw water quality report and clarify the types and concentrations of anionic ions.Focus on total hardness, total alkalinity, strong acid anion content, silica content, and organic matter concentration.The alkalinity of raw water is high, and the pre-weakly acidic yang resin can be considered to reduce costs by using its low acid consumption characteristics.If the raw water has a high content of organic matter, it is necessary to choose an anti-pollution yin resin to avoid rapid pollution and failure.
Seasonal fluctuations should also be considered.In systems with surface water as the source of water, the content of suspended solids and organic matter rises in the rainy season, the salt content may decrease, and the salt content increases during the dry period.The selection of the type needs to reserve a certain margin to adapt to the fluctuation range and avoid frequent substandard water output.
Match the Resin Type According to the Processing Requirements
This strong acid yang resin is the basis of the desalination system and is responsible for removing all cations. Almost all fixed bed Yang beds will be selected.
This weak acid yang resin is suitable for pre-processing of high alkalinity raw water, mainly removing carbonate hardness, and low regenerative acid consumption, which can reduce the load on subsequent strong acid yang resin.When the alkalinity of raw water accounts for more than 50% of the total anion ratio, the addition of a weak acid anode bed usually has economic value.
This strong alkaline anion resin is responsible for removing all anions, including silicate, and is an essential material for deep desalination.When the system has silicon removal requirements, a strong alkaline anion resin must be used.
This weakly alkaline anion resin can only remove strong acid anions. It has low alkali consumption and strong resistance to organic pollution. It is suitable for placement in front of the strong alkaline anion resin to absorb most of the strong acid anions and some organic matter to protect the strong alkaline resin and extend its life.
This mixed bed resin is used for terminal polishing.It needs to be matched with a special mixed bed resin with good uniformity and high mechanical strength to ensure thorough regeneration and stratification, uniform operation and mixing, and stable high-purity water quality.
Pay Attention to the Core Performance Indicators of the Resin
- Full exchange capacity: The total amount of ions that can be exchanged per unit mass or volume of resin is the theoretical upper limit of the exchange capacity, per unit mmol/g dry base or mmol/mL wet base.The full exchange capacity of conventional strongly acidic anionic resins is generally not less than 1.9 mmol/mL in volume, and strongly alkaline anionic resins are not less than 1.3 mmol/mL.
- Resin working exchange capacity: The effective exchange capacity that the resin can exert under actual operating conditions is affected by water quality, flow rate, and regeneration level, and is usually only 60% to 80% of the full exchange capacity.It directly determines the operating cycle and the amount of water processed, and is the core basis for the selection and calculation.
- Resin moisture content: The water content inside the resin particles is related to the degree of crosslinking and the number of functional groups.The moisture content is within a reasonable range, the pore structure is more stable, and the exchange performance is better.
- Particle size distribution and uniformity coefficient: reflect particle size and uniformity.The smaller the uniformity coefficient, the more uniform the particles, the more uniform the water flow distribution, the lower the bed temperature drop, and the better the regeneration effect.The uniformity coefficient of conventional industrial resins is generally below 1.6, and high-end homogeneous resins can be controlled within 1.1.
- Regeneration efficiency: The proportion of the exchange capacity restored after regeneration to the theoretical capacity.The higher the regeneration efficiency, the longer the operating cycle, the higher the chemical utilization rate and the lower the cost.
- Good chemical and physical stability: The resin needs to withstand regenerative acid-base corrosion, withstand water erosion and temperature changes, and is not easy to break.Resins with poor mechanical strength will break in large quantities after 1 to 2 years of operation, causing the bed lamination to drop and the water outlet to bring resin, which needs to be replaced in advance.
Combining Operating Conditions and System Design
The performance of resin is inseparable from reasonable system design and operating conditions.The operating flow rate and contact time directly affect the exchange effect.The conventional flow rate of the yang bed and the yin bed is 15 to 30 m/h, and the flow rate is too high, which will lead to insufficient exchange and early leakage.As a polishing unit, the flow rate of the mixed bed can be appropriately increased, and it is generally controlled at 20 to 50 m/h.
The bed height and filling capacity are the core parameters of the system design.The height of the bed of the fixed bed, the yang-yin bed, is usually not less than 800 mm, and the height of the high-load system is recommended to be 1200 to 1500 mm to ensure sufficient contact time and ion leakage buffer zone.The regeneration frequency is calculated based on the salt content of raw water and the working exchange capacity.If the cycle is too short, it will increase chemical consumption and labor costs, and if it is too long, it will easily exceed the standard.Generally, it is more reasonable to control the cycle of a single-stage sun bed from 8 to 24 hours.
The water temperature, water inlet pH, and bed lamination drop will also affect the resin properties.If the water temperature is too low, the exchange speed will be reduced and the capacity will decrease.If the suspended solids in the water are too high, they will clog the pores of the resin and cause the pressure drop to increase.These factors must be taken into account when selecting models.
[Not sure which resin configuration fits your raw water profile? Share your water quality report with COMCESS engineers for a free resin selection, capacity calculation, and cost-optimization plan.]
Resin Regeneration and Daily Maintenance of the System
The resin exchange capacity is limited, and it needs to be regenerated and restored after adsorption and saturation.Standardize regeneration and daily maintenance in order to ensure the stable operation of the system and extend the life of the resin.
Regeneration Methods and Processes
Cationic resin regeneration usually uses hydrochloric acid or sulfuric acid.Hydrochloric acid has a stable regeneration effect and does not produce precipitation. It is the most commonly used regeneration agent.The price of sulfuric acid is lower, but the concentration is too high, it is easy to precipitate calcium sulfate with calcium ions, and the concentration needs to be increased step by step to regenerate.Sodium hydroxide solution is generally used for the regeneration of anionic resins.For strong alkaline anointed resins with silicon removal requirements, the temperature of the regeneration solution is increased to 35 to 40℃, which can improve the elution effect of silicon and reduce residues.
The complete regeneration process is divided into five steps.Backwash enters water from the bottom of the tank, loosens the resin layer, and flushes out suspended solids and broken particles.The regenerating agent slowly passes through the resin layer at a set concentration and flow rate to complete the replacement.The replacement water pushes the regenerated liquid to continue the reaction at the same flow rate.Positive washing is rinsed from top to bottom to wash away residual regenerating agents and regenerating products.Finally, rinse until the effluent is qualified, and the system is restarted.The regeneration efficiency is affected by the amount, concentration, flow rate, and contact time. It is not that the more you add, the better. Excessive addition will only increase the cost.
Common Operating Abnormalities
Due to the early failure of the resin, the cycle is shortened.The common reasons are the increase in salt content of raw water, insufficient regeneration, or the resin is contaminated and oxidized, resulting in a decrease in capacity.
The conductivity of domestic water production continues to be high.It may be that the resin has not been regenerated in time after failure, or it may be that the purity of the regenerator is not enough, the resin layer is biased, and the water distribution device is damaged, causing a short flow, and part of the water enters the water and flows out directly without the resin.
Prevent silica leakage.It mostly appears in yin beds and mixed beds, usually because the amount of regenerated alkali is insufficient, the temperature of the regenerated liquid is not enough, or the flow rate is too high, and the silicate is not fully adsorbed.
There is no organic pollution and iron pollution.Humic acid and fulvic acid are adsorbed on the yin resin and are difficult to elute, the color of the resin darkens and the capacity decreases.Iron ions contaminate the Yang resin, forming iron compounds deposited inside, causing permanent capacity loss.
The resin is broken.After multiple regeneration, expansion and contraction, and water erosion, the resin will gradually break, and it is normal to control the annual breaking rate within 5%.A large amount of crushing in a short period of time may be due to large fluctuations in water inlet pressure, excessive backwash strength, or oxidation and degradation of the resin.
Methods to Extend the Life of The Resin
It is the basis to do a good job in the pretreatment of water inlet, and strictly control the content of suspended solids, residual chlorine, iron, and organic matter in the water inlet.If the residual chlorine exceeds 0.1 mg/L, it will oxidize the positive resin, and it needs to be removed with activated carbon in advance.Standardize the regeneration operation, perform it according to the designed concentration, dosage, and flow rate, ensure the contact time, and regularly heat up the yin resin to wash the silicon.Continuously monitor the water production, water inlet and outlet conductivity, pressure drop, and amount of regenerator, and judge the state of the resin through data changes.Samples are taken every year to test the exchange capacity and crushing rate, and the remaining life is evaluated.Generally, industrial resins have a life span of 3 to 5 years, and can be used for 5 to 8 years if properly maintained.
[Experiencing frequent resin regeneration, silica leakage, or shortened operating cycles? Upgrade to COMCESS high-stability ion exchange resins to extend service life up to 8 years and cut chemical consumption.]
.png)
Typical Industrial Applications
Use electricity to generate electricity.Boiler supply water is the largest application scenario for desalination water.High-pressure and ultra-high-pressure power station boilers have extremely high requirements for hardness, silicon, and conductivity. They usually use a full ion exchange process or a reverse osmosis mixed bed process to ensure steam quality.
Semiconductor electronics and semiconductor.Chip wafer manufacturing requires a lot of ultrapure water, and the purity of the water used for cleaning directly affects the yield.The system takes reverse osmosis as the main body, and the end is equipped with a multi-stage mixed bed or EDI polishing to produce ultrapure water with a resistivity of 18.2MW·cm.
Biopharmaceuticals.Purified water and water for injection must meet the standards of the Pharmacopoeia, and the content of microorganisms, endotoxins, and ions is strictly required.Ion exchange is often combined with reverse osmosis and distillation to control ionic impurities within the limit.
Chemical industry and food and beverage.High-purity water is required for the reaction and refining of fertilizers and fine chemicals to avoid impurity ions from affecting the reaction and quality.Desalinated water for beverages and beer brewing adjusts the hardness and ion composition to ensure consistent flavor; desalinated water for dairy products avoids minerals from affecting protein stability.
National laboratories and testing institutions.Analytical experiments and instrument testing require high-purity water to avoid impurities interfering with the results.The small ion exchange water purifier can produce secondary water and primary water to meet the experimental needs of titration, chromatography, mass spectrometry, etc.
Summary
The core of the resin selection of the desalination system is to adapt to the raw water quality, water production requirements and operating conditions, not the more expensive the better.A stable desalination system requires the cooperation of pretreatment, process configuration, resin selection, regeneration and maintenance. Any disconnect will affect the water quality and operating costs of the effluent.
COMCESS provides a full range of yang resins, yin resins and mixed bed ion exchange resins, which are suitable for various industrial desalination systems.We can complete the resin selection, filling and regeneration parameter calculation based on raw water data, control operating costs, and provide technical support such as selection evaluation and fault diagnosis.If you have new construction or system optimization needs, you can contact to communicate water quality requirements and solutions.
[Ready to optimize your water demineralization system? From standard two-bed setups to 18.2 MΩ·cm ultrapure mixed-bed polishing, COMCESS delivers high-capacity resins and tailored engineering support—contact us today for a custom quote.]